RFID for Access Control
Balluff provides several industrial RFID systems as well as custom built solutions that can be used to provide access control for the manufacturing and process industries. These RFID solutions include systems that can be used to identify operators and maintenance personnel for enabling or locking out equipment or machinery that not only act as a key but also indentify the individual and clearance level to control systems. RFID systems are also available that identify process equipment such as piping and connectors to verify they are being connected in the correct sequence and by proper connection point to provide a reliable means of preventing mixing of the wrong contents or improper connections for a given process. With the most communication options available for flexible and easy integration and the most reader head/tag flexibility vs. range and mounting positions, Balluff’s BIS systems make it easy to integrate RFID into any of today’s manufacturing or process control systems.
Start your selection here:
Step 1: What are you trying to track?
- Process Access
- Robust, flexible, environmentally rugged - BIS C
- Lower cost, low memory capacity, read-only options - BIS L
- Long range, ISO compliant, high speed - BIS M
On parts
- Robust, flexible, environmentally rugged - BIS C
- Lower cost, low memory capacity, read-only options - BIS L
- Long range, ISO compliant, high speed - BIS M
Security
- Robust, flexible, environmentally rugged - BIS C
- Long range, ISO compliant, high speed - BIS M
Step 2: Select your data carrier (using links from tables below) Step 3: Select read/write heads (using links below each chart) Step 4: Select processors (using links below each chart)
Process Access
|
|
Carriers |
R/W Function |
Max. read/write distance |
Memory |
Mountable in metal |
Image |
|
.BIS C Read/write2 times of 220/860 ms, for operating temperatures between -30°C and +70°C1 (-22°F and +158°F), 1 million write cycles guaranteed, dynamic. |
|
| BIS C-127-05/L |
R/W |
30 mm |
1023 Byte |
Not in metal |
 |
|
BIS C-122-11/L |
R/W |
7 mm |
2047 Byte |
Not in metal |
 |
|
BIS C-122-04/L |
R/W |
3 mm |
511 Byte |
Not in metal |
 |
|
BIS C-121-04/L |
R/W |
2 mm |
511 Byte |
Not in metal |
 |
|
BIS C - Hardware Cross-Reference (.pdf) Step 3: Select BIS C read/write head Step 4: Select BIS C processor  |
|
1 = Extended temperatures up to 120°C for BIS C tags on request. 2 = Read/write times are for 64 bytes of data including data check.
|
|
Carriers |
R/W Function |
Max. read/write distance |
Memory |
Static or dynamic use |
Image |
|
.BIS L Read/write times of 1530/35301 ms, for operating temperatures between -25°C and +85°C (-13°F and +185°F), 100,000 write cycles guaranteed, mountable in metal. |
|
| BIS L-102-01/L |
R/W |
70 mm |
192 Byte |
Static only |
 |
| BIS L-101-01/L |
R/W |
55 mm |
192 Byte |
Static only |
 |
| BIS L-150-05/A † |
R/W |
40 mm |
192 Byte |
Static only |
 |
| BIS L-100-01/L |
R/W |
40 mm |
192 Byte |
Static only |
 |
| BIS L-103-05/L |
R/W |
30 mm |
192 Byte |
Static only |
 |
| BIS L-102-05/L-RO2 |
Read only |
55 mm |
192 Byte |
Dynamic |
 |
| BIS L-202-03/L2 |
Read only |
55 mm |
5 Byte |
Dynamic |
 |
| BIS L-101-05/L-RO2 |
Read only |
40 mm |
192 Byte |
Dynamic |
 |
| BIS L-100-05/L-RO2 |
Read only |
30 mm |
192 Byte |
Dynamic |
 |
| BIS L-201-03/L2 |
Read only |
30 mm |
5 Byte |
Dynamic |
 |
| BIS L-103-05/L-RO2 |
Read only |
23 mm |
192 Byte |
Dynamic |
 |
| BIS L-200-03/L2 |
Read only |
23 mm |
5 Byte |
Dynamic |
 |
| BIS L-203-03/L2 |
Read only |
23 mm |
5 Byte |
Dynamic |
 |
BIS L - Hardware Cross-Reference (.pdf) Step 3: Select BIS L read/write heads  Step 4: Select BIS L read only processor Select BIS L processor  |
|
1 = Read/write times are for 64 bytes of data (incl. data check) for read/write tags only. 2 = Max. read speed of 72 meters/min.
|
|
Carriers |
R/W Function |
Max. read/write distance |
Memory |
Mountable in metal |
Image |
|
.BIS M Read/write2 times of 60/130 ms, for operating temperatures between -25°C and +70°C (-13°F and +158°F), 100,000 or >100 million write cycles guaranteed, dynamic. |
|
| BIS M-110-02/L* |
R/W |
32 mm |
2000 Byte |
Not in metal |
 |
|
BIS M-105-01/A |
R/W |
9 mm |
752 Byte |
In metal |
 |
|
BIS M-105-02/A* |
R/W |
9 mm |
752 Byte |
In metal |
 |
| BIS M-122-01/A† |
R/W |
9 mm |
752 Byte |
In metal |
 |
|
BIS M-122-02/A* † |
R/W |
7 mm |
2000 Byte |
In metal |
 |
BIS M - Hardware Cross-Reference (.pdf) Step 3: Select BIS M read/write heads  Step 4: Select BIS M processor
|
* = >100 million write cycles guaranteed. † = For harsh environments. 1 = Extended temperatures up to 130°C for BIS M tags. 2 = Read/write times are for 64 bytes of data including data check.
|
Part ID
|
|
Carriers |
R/W Function |
Max. R/W distance |
Memory |
Mountable in metal |
Image |
|
.BIS C Read/write2 times of 220/860 ms, for operating temperatures between -30°C and +70°C (-22°F and +158°F)1, 1 million write cycles guaranteed, dynamic, mountable in metal, for harsh environments. |
|
| BIS C-127-05/L |
R/W |
30 mm |
1023 Byte |
Not in metal |
 |
|
BIS C-122-11/L |
R/W |
7 mm |
2047 Byte |
Not in metal |
 |
|
BIS C-122-04/L |
R/W |
3 mm |
511 Byte |
Not in metal |
 |
|
BIS C-121-04/L |
R/W |
2 mm |
511 Byte |
Not in metal |
 |
BIS C - Hardware Cross-Reference (.pdf) Step 3: Select BIS C read/write head Step 4: Select BIS C processor  |
|
† = Rated for vacuum service 1 = Extended temperatures up to 120°C for BIS C tags on request. 2 = Read/write times are for 64 bytes of data including data check.
|
|
Carriers |
R/W Function |
Max. read/write distance |
Memory |
Static or Dynamic |
Image |
|
.BIS L Read/write times of 1530/35301 ms, for operating temperatures between -25°C and +85°C (-13°F and +185°F), 100,000 write cycles guaranteed, mountable in metal. |
|
| BIS L-150-05/A † |
R/W |
40 mm |
192 Byte |
Static only |
 |
| BIS L-102-05/L-RO2 |
Read only |
55 mm |
192 Byte |
Dynamic |
 |
| BIS L-202-03/L2 |
Read only |
55 mm |
5 Byte |
Dynamic |
 |
| BIS L-101-05/L-RO2 |
Read only |
40 mm |
192 Byte |
Dynamic |
 |
| BIS L-100-05/L-RO2 |
Read only |
30 mm |
192 Byte |
Dynamic |
 |
| BIS L-201-03/L2 |
Read only |
30 mm |
5 Byte |
Dynamic |
 |
| BIS L-103-05/L-RO2 |
Read only |
23 mm |
192 Byte |
Dynamic |
 |
| BIS L-200-03/L2 |
Read only |
23 mm |
5 Byte |
Dynamic |
 |
| BIS L-203-03/L2 |
Read only |
23 mm |
5 Byte |
Dynamic |
 |
BIS L - Hardware Cross-Reference (.pdf) Step 3: Select BIS L read/write heads  Step 4: Select BIS L read only processor Select BIS L processor  |
|
† =Not mountable in metal. 1 = Read/write times are for 64 bytes of data (incl. data check) for read/write tags only. 2 = Max. read speed of 72 meters/min.
|
|
Carriers |
R/W Function |
Max. read/write distance |
Memory |
Mountable in metal |
Image |
|
.BIS M Read/write2 times of 60/130 ms, for operating temperatures between -25°C and +70°C (-13°F and +158°F), 100,000 or >100 million write cycles guaranteed, dynamic. |
|
| BIS M-107-03/L-H200* † 1 |
R/W |
30 mm |
112 Byte |
Not in metal |
 |
| BIS M-115-03/A* |
R/W |
30 mm |
112 Byte |
In metal |
 |
|
BIS M-105-01/A |
R/W |
9 mm |
752 Byte |
In metal |
 |
|
BIS M-105-02/A* |
R/W |
9 mm |
752 Byte |
In metal |
 |
| BIS M-122-01/A† |
R/W |
9 mm |
752 Byte |
In metal |
 |
|
BIS M-122-02/A* † |
R/W |
7 mm |
2000 Byte |
In metal |
 |
BIS M - Hardware Cross-Reference (.pdf) Step 3: Select BIS M read/write heads  Step 4: Select BIS M processor
|
* = >100 million write cycles guaranteed. † = For harsh environments. 1 = Extended temperatures up to 130°C for BIS M tags. 2 = Read/write times are for 64 bytes of data including data check.
|
Security
|
|
Carriers |
R/W Function |
Max. read/write distance |
Memory |
Mountable in metal |
Image |
|
.BIS C Read/write2 times of 220/860 ms, for operating temperatures between -30°C and +70°C1 (-22°F and +158°F), 1 million write cycles guaranteed, dynamic. |
|
| BIS C-127-05/L |
R/W |
30 mm |
1023 Byte |
Not in metal |
 |
|
BIS C - Hardware Cross-Reference (.pdf) Step 3: Select BIS C read/write head Step 4: Select BIS C processor  |
|
1 = Extended temperatures up to 120°C for BIS C tags on request. 2 = Read/write times are for 64 bytes of data including data check.
|
|
Carriers |
R/W Function |
Max. read/write distance |
Memory |
Mountable in metal |
Image |
|
.BIS M Read/write2 times of 60/130 ms, for operating temperatures between -25°C and +70°C (-13°F and +158°F), 100,000 or >100 million write cycles guaranteed, dynamic. |
|
| BIS M-120-01/L |
R/W |
50 mm |
752 Byte |
Not in metal |
 |
BIS M - Hardware Cross-Reference (.pdf) Step 3: Select BIS M read/write heads  Step 4: Select BIS M processor
|
1 = Extended temperatures up to 130°C for BIS M tags. 2 = Read/write times are for 64 bytes of data including data check. |
|
|
|
|
|
|